ABSTRACT
OBJECTIVES: The prolonged presence of infectious SARS-CoV-2 in deceased patients with COVID-19 has been reported. However, infectious virus titers have not been determined. Such information is important for public health, death investigation, and handling corpses. The aim of this study was to assess the level of SARS-CoV-2 infectivity in the corpses of patients with COVID-19. METHODS: We collected 11 nasopharyngeal swabs and 19 lung tissue specimens from 11 autopsy cases with COVID-19 in 2021. We then investigated the viral genomic copy number by real-time reverse transcription-polymerase chain reaction and infectious titers by cell culture and virus isolation. RESULTS: Infectious virus was present in six of 11 (55%) cases, four of 11 (36%) nasopharyngeal swabs, and nine of 19 (47%) lung specimens. The virus titers ranged from 6.00E + 01 plaque-forming units/ml to 2.09E + 06 plaque-forming units/g. In all cases in which an infectious virus was found, the time from death to discovery was within 1 day and the longest postmortem interval was 13 days. CONCLUSION: The corpses of patients with COVID-19 may have high titers of infectious virus after a long postmortem interval (up to 13 days). Therefore, appropriate infection control measures must be taken when handling corpses.
Subject(s)
COVID-19 , Communicable Diseases , Humans , COVID-19/diagnosis , SARS-CoV-2 , Lung , COVID-19 Testing , CadaverABSTRACT
Rapid and accurate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in dead bodies is essential to prevent infection among those working with dead bodies. This study focused on the Smart Amplification (SmartAmp) method, which has a short examination time (approximately an hour), is simple to perform, and demonstrates high specificity and sensitivity. This method has already been used for clinical specimens; however, its effectiveness in dead bodies has not been reported. This study examined the SmartAmp method using 11 autopsies or postmortem needle biopsies performed from January to May, 2021 (of these, five cases tested positive for SARS-CoV-2 by quantitative real-time polymerase chain reaction (qRT-PCR) and six cases tested negative). Swab samples were collected from the nasopharynx, oropharynx, or anus and the SmartAmp and qRT-PCR results were compared. For the nasopharynx and oropharynx samples, the same results were obtained for both methods in all cases; however, for the anal swabs, there was one case that was positive according to qRT-PCR but negative according to the SmartAmp method. The SmartAmp method may therefore be less sensitive than qRT-PCR and results may differ in specimens with a low viral load, such as anal swabs. However, in the nasopharynx and oropharynx specimens, which are normally used for testing, the results were the same using each method, suggesting that the SmartAmp method is useful in dead bodies. In the future, the SmartAmp method may be applied not only during autopsies, but also in various situations where dead bodies are handled.